Total Energy Conservation Products |
HVAC Commercial Applications |
Retro Fit Packaged Systems |
Commercial Evaporative Condenser Cooling |
Commercial Evaporative Subcooling |
These designs are to Retro fit with your existing Roof Top HVAC system. This will subcool the existing Roof Top Units condenser(s). One Tower is designed to subcool several Roof Top Units at one time. Our Commercial product orders are generally the same but their are different size compressors. We will design a energy efficient system to retro fit your existing layout and save thousands. Most cases we can down size the compressor to even save more. |
Quick & Easy Retro Fit Energy Saving Solutions |
This application is designed for a small Convenient Store, Restaurant, and also having refrigeration. This is layout is simple; will handle the stores HVAC and walk-in cooler, wall mount refrigeration. (up to 15 tons). Simple retro fit installation using an Evaporative Condenser Cooling Tower with up to three evaporative cooling coils. The Heat Exchanger coils adapt to existing R-22 refrigerant (Freon) system. Should be able to use existing Freon lines. The tower and pump is wired 220v. You must supply water to the tower and connect to our stainless steel flex 1/2” female fitting. |
Not Sure - Get an Energy Survey |
These designs are to Retro fit with your existing Roof Top Units (RTU’s) HVAC systems and will use an Evaporative Fluid Cooling Tower to Subcool the existing refrigerant circuits. All designs may include any refrigeration system with the compressors installed on the roof. Knowing how many RTU’s and how many Refrigeration compressors we can design a super energy saving package. These packages below can utilize one or more towers. For each existing RTU and/or refrigerant compressor, we include a matching Water/Freon Heat Exchanger. |
What is a Freon/Water Heat Exchanger? This is a component that receives the cold water from the Evaporative Subcooling Tower and inter-circles the Freon line to cools it before going to the condenser (compressor). |
Need Help? Call (512) 704-8200 |
Need Help? Call (512) 704-8200 |
Placement Planning:
Our Evaporative Fluid Cooler may be installed remotely, away from the loop. This choice may require a Flow Switch (supplied). This flow and temperature control will turn on/off Tower pump and fan.
Water access needs to be considered. You will be connecting into a ¾ stainless steel standard female thread fitting.
Ball valve is in place to divert flow to the tower from the loop. The tower should be able to handle all of the flow or you can open the valve a little bit to allow water to by pass the tower if the tower restricts the flow too much. Just open the by pass ball valve little by little so most of the flow goes to the tower.
The Product:
All loop connections are 1 ½ PVC. You will connect into a Slip joint.
Attractive all fiberglass cabinet cannot corrode. Never requires painting. Air inlet windows designed to keep sunlight out which eliminates algae growth to help eliminate maintenance concerns. Fiberglass basin designed to eliminate freeze damage. Pump is protected by low wattage heat strips. High efficiency evaporative fluid copper coil design, commercial PVC evaporative media & Fittings, water Spray Nozzles, Durable plastic, non-corrosive and non-fouling. Aluminum body Fans, High Efficiency multi-speed motors, epoxy coated frame, precision balanced plastic blades for quiet, trouble-free service and salt air resistant.
Manufacture offers a 15 Year Warranty on the unit, 3 years on the pump and fan. |
All Prices FOB Austin, TX or Chula, GA Freight Collect |
The designs and layouts shown are examples of some of our simple retro fit solutions. As most all of the Commercial Packaged Roof Top Units (RTU’s) HVAC Air Conditioners installed and in service today are basically the same. Knowing how many RTU’s and the compressor sizes you have we can give you a quick product price and basic layout. We also have add-ons when using our evaporative cooling tower. Products to even add greater energy savings. Depending on what you have, we can also include a Pre-Cool Make-up Air subcooler, a Thermal Rain Battery Collection, and incorporate with any Store or Warehouse Refrigeration that may be installed. |
Theses applications are designed for a medium box style buildings, Pharmacy's, Small Grocery Stores, having multiple RTU’s and with or without store refrigeration. Simple retro fit installation of an Evaporative Subcooling Tower and Water/Freon Heat Exchangers that adapt to existing R-22 refrigerant (Freon) system. Should be able to use existing Freon lines. The tower and pump is wired 220v. You must supply water to the tower and connect to our stainless steel flex 1/2” female fitting. |
Our simple retro fit solution will save thousands in energy cost. |
No matter how the existing layout looks, we can retro fit them. |
Example retrofit using 4 Evaporative Fluid Coolers subcooling 12 large RTU’s. |
A poor layout installation design like this is costing thousands to operate. These units are trying to cool hot refrigerant pipes with hot air.
Confined installation traps the hot air then recycles it to try and cool again. This alone and take into consideration the Urban Heat Island effect, these units are in need of an Evaporative Fluid Cooling Tower. We make comfort affordable and energy efficient. |